For the CHARMM form must be given in Kcal mol rad, while is the equilibrium angle of the improper torsion in degree.
For the AMBER form the meaning of the symbol are identical to those described in the TORSION PROPER directive.
TORSION IMPROPER x x ca h4 1.1000 2.0 180.0 cosine x x ca h5 1.1000 2.0 180.0 ck cb n* ct 1.0000 2.0 180.0 cosine cm c n* ct 1.0000 2.0 180.0 cosine ha cpa cpa cpm 29.40 0.0 harmonic ha cpb c c 20.00 0.0 harmonic ha ha c c 20.00 180.0 harmonic END
procacci 2021-12-29